Product Features

Stable Power Output

The LN1250N-BL combines 12V, 50Ah, 600Wh for dependable operation in lead-acid battery replacement and deep-cycle equipment.

Application-Ready Integration

For the LN1250N-BL sodium-ion lead-acid replacement battery, integration details include terminals: M6; protection: IP65; display: Regular LCD screen, helping project teams plan the electrical and mechanical interface.

Defined Service Conditions

The LN1250N-BL sodium-ion lead-acid replacement battery service limits are cycle life: ≥4000; charge temperature: -10~+60°C; discharge temperature: -30~+60°C; dimensions: 229×144×213mm; weight: 8kg, supporting safe system design and maintenance planning.

OEM/ODM Engineering Support

Hysincere can review BMS, connector, wiring, enclosure, communication, labeling, and packaging requirements for the LN1250N-BL sodium-ion lead-acid replacement battery.

Hysincere sodium replacing lead acid battery application scenario for outdoor and low temperature energy use

LN1250N-BL Power for Lead-Acid Battery Replacement And Deep-Cycle Equipment

For lead-acid battery replacement and deep-cycle equipment, the LN1250N-BL provides 12V / 50Ah / 600Wh in a sodium-ion lead-acid replacement battery platform. Project integration should confirm load profile, charger settings, protection coordination, and installation constraints.

For lead-acid battery replacement and deep-cycle equipment, the LN1250N-BL provides 12V / 50Ah / 600Wh in a sodium-ion lead-acid replacement battery platform. Project integration should confirm load profile, charger settings, protection coordination, and installation constraints.

Hysincere battery smart BMS protection technology for LiFePO4 and energy storage battery systems

Electrical Performance and Protection

For the LN1250N-BL sodium-ion lead-acid replacement battery, the confirmed electrical limits are maximum charge voltage 15.6V; discharge cut-off voltage 8V; maximum charge current 50A; continuous discharge current 50A; peak discharge current 100A. Charger, fuse, cable, and BMS settings must be coordinated with the complete system.

For the LN1250N-BL sodium-ion lead-acid replacement battery, the confirmed electrical limits are maximum charge voltage 15.6V; discharge cut-off voltage 8V; maximum charge current 50A; continuous discharge current 50A; peak discharge current 100A. Charger, fuse, cable, and BMS settings must be coordinated with the complete system.

Hysincere deep cycle battery life technology visual for long-lasting rechargeable battery performance

Integration, Environment and Service Life

The LN1250N-BL sodium-ion lead-acid replacement battery is specified with cycle life: ≥4000; charge temperature: -10~+60°C; discharge temperature: -30~+60°C; dimensions: 229×144×213mm; weight: 8kg. Integration options include terminals: M6; protection: IP65; display: Regular LCD screen; project-specific changes require final engineering confirmation.

The LN1250N-BL sodium-ion lead-acid replacement battery is specified with cycle life: ≥4000; charge temperature: -10~+60°C; discharge temperature: -30~+60°C; dimensions: 229×144×213mm; weight: 8kg. Integration options include terminals: M6; protection: IP65; display: Regular LCD screen; project-specific changes require final engineering confirmation.

Technical Specifications

LN1250N-BL 12V 50Ah sodium-ion lead-acid replacement battery Product Parameters

Main Parameters
ModelLN1250N-BLNominal Voltage12V
Maximum Charge Voltage15.6VDischarge Cut-off Voltage8V
Nominal Capacity50AhRated Energy600Wh
Electrical Performance
Maximum Charge Current50AMaximum Continuous Discharge Current50A
Maximum Peak Discharge Current (5S)100AMaximum Series & Parallel4S4P
Temperature & Protection
Charge Temperature-10~+60°CDischarge Temperature-30~+60°C
IP Rating of EnclosureIP65Protection LevelIP65
Physical & Installation
TerminalsM6Dimension229*144*213mm
Weight8kg
Lifecycle & Compliance
Cycle Life≥4000LCD ScreenRegular LCD screen

LN1250N-BL Frequently Asked Questions

Technical answers about the LN1250N-BL sodium-ion lead-acid replacement battery, including electrical ratings, charging, installation, operating conditions, and OEM/ODM integration.

What is the LN1250N-BL designed for?

The LN1250N-BL is a sodium-ion lead-acid replacement battery intended for lead-acid battery replacement and deep-cycle equipment. System selection should confirm the equipment voltage, continuous and peak load, installation space, and required certifications.

What are the key electrical specifications of the LN1250N-BL?

The confirmed core ratings are 12V, 50Ah, 600Wh. Electrical limits include maximum charge voltage 15.6V; discharge cut-off voltage 8V; maximum charge current 50A; continuous discharge current 50A; peak discharge current 100A. Use the final approved specification for charger and protection settings.

How should the LN1250N-BL be charged and protected?

Use a charger and protection strategy matched to the battery chemistry, voltage, and current limits. For this model, the relevant limits are maximum charge voltage 15.6V; discharge cut-off voltage 8V; maximum charge current 50A; continuous discharge current 50A; peak discharge current 100A. Verify connector polarity, cable sizing, fuse selection, and BMS communication before commissioning.

What installation and environmental details apply to the LN1250N-BL?

The confirmed physical and service information is cycle life: ≥4000; charge temperature: -10~+60°C; discharge temperature: -30~+60°C; dimensions: 229×144×213mm; weight: 8kg. Allow adequate ventilation, mechanical support, service clearance, and protection appropriate to the operating environment.

Can the LN1250N-BL be customized for OEM or ODM projects?

Yes. Hysincere can evaluate connector, wiring, enclosure, BMS, communication, label, and packaging requirements. Current integration information is terminals: M6; protection: IP65; display: Regular LCD screen. Final feasibility and specifications are confirmed through engineering review.

Contact Us

Tell Us About Your Battery Project

Share your battery requirements with us, and our team will help you find the right solution.