High energy density
Integrated design with inverter, convenient for user operation
Excellent performance in charging and discharging at large current
Long working life, reducing maintenance cost
Multiple protection functions. high voltage protection, low voltage protection, over current protection,
high temperature protection, short circuit protection. reverse connection protection, ESD protection
Data transmission and parallel networking With RS485 and RS232 port
Accurate calculation of SOC and SOH
Model: | HX48100I 16S2P |
Nominal Voltage: | 51.2V |
Nominal Capacity: | 100Ah |
Minimum Capacity: | ≥96Ah |
Rated Energy: | 5120Wh |
Operating Voltage: | 44.8-58.4V |
Rated Voltage: | 51.2V |
Maximum Charge Voltage: | 58.4V |
Resistance: | IR≤0.6mΩ |
Maximum Charge Current: | 50A |
Maximum Continuous Discharge Current: | 100A |
Maximum Peak Discharge Current (5 seconds): | 200A |
Discharge Cut-off Voltage: | 43.2V |
Charge Temperature: | 0~+55℃ |
Discharge Temperature: | -20~+60℃ |
Storage Temperature: | -10~+45℃ |
Self Discharge (Stored at 50%SOC): | ≤3%/month |
Cycle Life (25℃, 0.5C, 100% DOD): | >5000 |
Dimensions: | 1020*440*150mm |
Weight: | 52kg |
Indicator Light: | Alarm/Operating/SOC |
Communication Protocol: | CAN/RS485/RS232 |
MPPT Voltage Range: | 120~450V |
Solar Charge Current: | 0~80A Optional |
Output Voltage: | 200V/208V/220V/240V |
Output Frequency: | 50HZ/60HZ |
Efficiency: | Input: >95% Output: >90% |
Protection Level: | IP54 |