Product Features

Stable Power Output

The LF126N-H combines 12.8V, 6Ah, 76.8Wh for dependable operation in lead-acid replacement and deep-cycle equipment.

Application-Ready Integration

For the LF126N-H LiFePO4 lead-acid replacement battery, integration details include terminals: F2; protection: IP67, helping project teams plan the electrical and mechanical interface.

Defined Service Conditions

The LF126N-H LiFePO4 lead-acid replacement battery service limits are cycle life: ≥4000; charge temperature: 0~+55°C; discharge temperature: -20~+60°C; dimensions: 90×72×100mm; weight: 0.7kg, supporting safe system design and maintenance planning.

OEM/ODM Engineering Support

Hysincere can review BMS, connector, wiring, enclosure, communication, labeling, and packaging requirements for the LF126N-H LiFePO4 lead-acid replacement battery.

Hysincere Regular Version Series LiFePO4 battery application scenario for home solar energy storage

LF126N-H Power for Lead-Acid Replacement And Deep-Cycle Equipment

For lead-acid replacement and deep-cycle equipment, the LF126N-H provides 12.8V / 6Ah / 76.8Wh in a LiFePO4 lead-acid replacement battery platform. Project integration should confirm load profile, charger settings, protection coordination, and installation constraints.

For lead-acid replacement and deep-cycle equipment, the LF126N-H provides 12.8V / 6Ah / 76.8Wh in a LiFePO4 lead-acid replacement battery platform. Project integration should confirm load profile, charger settings, protection coordination, and installation constraints.

Hysincere battery smart BMS protection technology for LiFePO4 and energy storage battery systems

Electrical Performance and Protection

For the LF126N-H LiFePO4 lead-acid replacement battery, the confirmed electrical limits are maximum charge voltage 14.6V; discharge cut-off voltage 10V; maximum charge current 6A; continuous discharge current 10A; peak discharge current 20A. Charger, fuse, cable, and BMS settings must be coordinated with the complete system.

For the LF126N-H LiFePO4 lead-acid replacement battery, the confirmed electrical limits are maximum charge voltage 14.6V; discharge cut-off voltage 10V; maximum charge current 6A; continuous discharge current 10A; peak discharge current 20A. Charger, fuse, cable, and BMS settings must be coordinated with the complete system.

Hysincere deep cycle battery life technology visual for long-lasting rechargeable battery performance

Integration, Environment and Service Life

The LF126N-H LiFePO4 lead-acid replacement battery is specified with cycle life: ≥4000; charge temperature: 0~+55°C; discharge temperature: -20~+60°C; dimensions: 90×72×100mm; weight: 0.7kg. Integration options include terminals: F2; protection: IP67; project-specific changes require final engineering confirmation.

The LF126N-H LiFePO4 lead-acid replacement battery is specified with cycle life: ≥4000; charge temperature: 0~+55°C; discharge temperature: -20~+60°C; dimensions: 90×72×100mm; weight: 0.7kg. Integration options include terminals: F2; protection: IP67; project-specific changes require final engineering confirmation.

Technical Specifications

LF126N-H 12.8V 6Ah LiFePO4 lead-acid replacement battery Product Parameters

Main Parameters
ModelLF126N-HNominal Voltage12.8V
Maximum Charge Voltage14.6VDischarge Cut-off Voltage10V
Nominal Capacity6AhRated Energy76.8Wh
Electrical Performance
Maximum Charge Current6AMaximum Continuous Discharge Current10A
Maximum Peak Discharge Current (5S)20AMaximum Series & Parallel1S4P
Temperature & Protection
Charge Temperature0~+55°CDischarge Temperature-20~+60°C
IP Rating of EnclosureIP67Protection LevelIP67
Physical & Installation
TerminalsF2Dimension90*72*100mm
Weight0.7kg
Lifecycle & Compliance
Cycle Life≥4000LCD ScreenNO
Certification(EU) 2023/1542 CE

LF126N-H Frequently Asked Questions

Technical answers about the LF126N-H LiFePO4 lead-acid replacement battery, including electrical ratings, charging, installation, operating conditions, and OEM/ODM integration.

What is the LF126N-H designed for?

The LF126N-H is a LiFePO4 lead-acid replacement battery intended for lead-acid replacement and deep-cycle equipment. System selection should confirm the equipment voltage, continuous and peak load, installation space, and required certifications.

What are the key electrical specifications of the LF126N-H?

The confirmed core ratings are 12.8V, 6Ah, 76.8Wh. Electrical limits include maximum charge voltage 14.6V; discharge cut-off voltage 10V; maximum charge current 6A; continuous discharge current 10A; peak discharge current 20A. Use the final approved specification for charger and protection settings.

How should the LF126N-H be charged and protected?

Use a charger and protection strategy matched to the battery chemistry, voltage, and current limits. For this model, the relevant limits are maximum charge voltage 14.6V; discharge cut-off voltage 10V; maximum charge current 6A; continuous discharge current 10A; peak discharge current 20A. Verify connector polarity, cable sizing, fuse selection, and BMS communication before commissioning.

What installation and environmental details apply to the LF126N-H?

The confirmed physical and service information is cycle life: ≥4000; charge temperature: 0~+55°C; discharge temperature: -20~+60°C; dimensions: 90×72×100mm; weight: 0.7kg. Allow adequate ventilation, mechanical support, service clearance, and protection appropriate to the operating environment.

Can the LF126N-H be customized for OEM or ODM projects?

Yes. Hysincere can evaluate connector, wiring, enclosure, BMS, communication, label, and packaging requirements. Current integration information is terminals: F2; protection: IP67. Final feasibility and specifications are confirmed through engineering review.

Contact Us

Tell Us About Your Battery Project

Share your battery requirements with us, and our team will help you find the right solution.