Product Features

Stable Power Output

The LF127N-H combines 12.8V, 7Ah, 89.6Wh for dependable operation in lead-acid replacement and deep-cycle equipment.

Application-Ready Integration

For the LF127N-H LiFePO4 lead-acid replacement battery, integration details include terminals: F2; protection: IP67, helping project teams plan the electrical and mechanical interface.

Defined Service Conditions

The LF127N-H LiFePO4 lead-acid replacement battery service limits are cycle life: ≥4000; charge temperature: 0~+55°C; discharge temperature: -20~+60°C; dimensions: 152×65×94mm; weight: 0.9kg, supporting safe system design and maintenance planning.

OEM/ODM Engineering Support

Hysincere can review BMS, connector, wiring, enclosure, communication, labeling, and packaging requirements for the LF127N-H LiFePO4 lead-acid replacement battery.

Hysincere Regular Version Series LiFePO4 battery application scenario for home solar energy storage

LF127N-H Power for Lead-Acid Replacement And Deep-Cycle Equipment

For lead-acid replacement and deep-cycle equipment, the LF127N-H provides 12.8V / 7Ah / 89.6Wh in a LiFePO4 lead-acid replacement battery platform. Project integration should confirm load profile, charger settings, protection coordination, and installation constraints.

For lead-acid replacement and deep-cycle equipment, the LF127N-H provides 12.8V / 7Ah / 89.6Wh in a LiFePO4 lead-acid replacement battery platform. Project integration should confirm load profile, charger settings, protection coordination, and installation constraints.

Hysincere battery smart BMS protection technology for LiFePO4 and energy storage battery systems

Electrical Performance and Protection

For the LF127N-H LiFePO4 lead-acid replacement battery, the confirmed electrical limits are maximum charge voltage 14.6V; discharge cut-off voltage 10V; maximum charge current 7A; continuous discharge current 10A; peak discharge current 20A. Charger, fuse, cable, and BMS settings must be coordinated with the complete system.

For the LF127N-H LiFePO4 lead-acid replacement battery, the confirmed electrical limits are maximum charge voltage 14.6V; discharge cut-off voltage 10V; maximum charge current 7A; continuous discharge current 10A; peak discharge current 20A. Charger, fuse, cable, and BMS settings must be coordinated with the complete system.

Hysincere deep cycle battery life technology visual for long-lasting rechargeable battery performance

Integration, Environment and Service Life

The LF127N-H LiFePO4 lead-acid replacement battery is specified with cycle life: ≥4000; charge temperature: 0~+55°C; discharge temperature: -20~+60°C; dimensions: 152×65×94mm; weight: 0.9kg. Integration options include terminals: F2; protection: IP67; project-specific changes require final engineering confirmation.

The LF127N-H LiFePO4 lead-acid replacement battery is specified with cycle life: ≥4000; charge temperature: 0~+55°C; discharge temperature: -20~+60°C; dimensions: 152×65×94mm; weight: 0.9kg. Integration options include terminals: F2; protection: IP67; project-specific changes require final engineering confirmation.

Technical Specifications

LF127N-H 12.8V 7Ah LiFePO4 lead-acid replacement battery Product Parameters

Main Parameters
ModelLF127N-HNominal Voltage12.8V
Maximum Charge Voltage14.6VDischarge Cut-off Voltage10V
Nominal Capacity7AhRated Energy89.6Wh
Electrical Performance
Maximum Charge Current7AMaximum Continuous Discharge Current10A
Maximum Peak Discharge Current (5S)20AMaximum Series & Parallel1S4P
Temperature & Protection
Charge Temperature0~+55°CDischarge Temperature-20~+60°C
IP Rating of EnclosureIP67Protection LevelIP67
Physical & Installation
TerminalsF2Dimension152*65*94mm
Weight0.9kg
Lifecycle & Compliance
Cycle Life≥4000LCD ScreenNO
Certification(EU) 2023/1542

LF127N-H Frequently Asked Questions

Technical answers about the LF127N-H LiFePO4 lead-acid replacement battery, including electrical ratings, charging, installation, operating conditions, and OEM/ODM integration.

What is the LF127N-H designed for?

The LF127N-H is a LiFePO4 lead-acid replacement battery intended for lead-acid replacement and deep-cycle equipment. System selection should confirm the equipment voltage, continuous and peak load, installation space, and required certifications.

What are the key electrical specifications of the LF127N-H?

The confirmed core ratings are 12.8V, 7Ah, 89.6Wh. Electrical limits include maximum charge voltage 14.6V; discharge cut-off voltage 10V; maximum charge current 7A; continuous discharge current 10A; peak discharge current 20A. Use the final approved specification for charger and protection settings.

How should the LF127N-H be charged and protected?

Use a charger and protection strategy matched to the battery chemistry, voltage, and current limits. For this model, the relevant limits are maximum charge voltage 14.6V; discharge cut-off voltage 10V; maximum charge current 7A; continuous discharge current 10A; peak discharge current 20A. Verify connector polarity, cable sizing, fuse selection, and BMS communication before commissioning.

What installation and environmental details apply to the LF127N-H?

The confirmed physical and service information is cycle life: ≥4000; charge temperature: 0~+55°C; discharge temperature: -20~+60°C; dimensions: 152×65×94mm; weight: 0.9kg. Allow adequate ventilation, mechanical support, service clearance, and protection appropriate to the operating environment.

Can the LF127N-H be customized for OEM or ODM projects?

Yes. Hysincere can evaluate connector, wiring, enclosure, BMS, communication, label, and packaging requirements. Current integration information is terminals: F2; protection: IP67. Final feasibility and specifications are confirmed through engineering review.

Contact Us

Tell Us About Your Battery Project

Share your battery requirements with us, and our team will help you find the right solution.