Product Features

Stable Power Output

Delivers 1200Wh rated energy for cold-weather outdoor power, RV backup power and lead-acid battery replacement applications.

Low Temperature Operation

Supports charging from -10~+60°C and discharging from -30~+60°C for reliable sodium battery performance in cold conditions.

Smart BMS Protection

Supports safer charge and discharge operation with intelligent battery management. Supports 100A continuous discharge and 200A peak discharge for demanding loads.

4S4P Connection Support

Supports 4S4P system connection for flexible lead-acid replacement and backup power system design.

Hysincere sodium replacing lead acid battery application scenario for outdoor and low temperature energy use

LN12100N-BL 12V 100Ah Sodium Battery for Cold Weather Lead-Acid Replacement

The LN12100N-BL is a 12V 100Ah Sodium Battery from the Hysincere Sodium Replacing Lead Acid Batteries, designed for cold-weather outdoor power, RV backup power and lead-acid battery replacement applications. It delivers 1200Wh rated energy with 100A continuous discharge performance.

The LN12100N-BL is a 12V 100Ah Sodium Battery from the Hysincere Sodium Replacing Lead Acid Batteries, designed for cold-weather outdoor power, RV backup power and lead-acid battery replacement applications. It delivers 1200Wh rated energy with 100A continuous discharge performance.

Hysincere battery smart BMS protection technology for LiFePO4 and energy storage battery systems

LN12100N-BL Smart BMS Protection for 100A Continuous Discharge

The LN12100N-BL is designed with smart BMS protection to support safer charge and discharge operation in cold-weather outdoor power, RV backup power and lead-acid battery replacement applications. It supports 100A continuous discharge, 200A peak discharge, IP65 protection, charging from -10~+60°C and discharging from -30~+60°C. It supports 4S4P configuration for flexible system design.

The LN12100N-BL is designed with smart BMS protection to support safer charge and discharge operation in cold-weather outdoor power, RV backup power and lead-acid battery replacement applications. It supports 100A continuous discharge, 200A peak discharge, IP65 protection, charging from -10~+60°C and discharging from -30~+60°C. It supports 4S4P configuration for flexible system design.

Hysincere deep cycle battery life technology visual for long-lasting rechargeable battery performance

LN12100N-BL ≥4000 Cycle Life Deep-Cycle Sodium Battery

The LN12100N-BL is built for long service life with ≥4000 cycle life, supporting stable rechargeable battery performance for B2B power applications. With 1200Wh rated energy, 100A continuous discharge and 5-year warranty support, it is suitable for reliable long-term use in cold-weather outdoor power, RV backup power and lead-acid battery replacement applications.

The LN12100N-BL is built for long service life with ≥4000 cycle life, supporting stable rechargeable battery performance for B2B power applications. With 1200Wh rated energy, 100A continuous discharge and 5-year warranty support, it is suitable for reliable long-term use in cold-weather outdoor power, RV backup power and lead-acid battery replacement applications.

Technical Specifications

LN12100N-BL Product Parameters

Main Parameters
ModelLN12100N-BLNominal Voltage12V
Maximum Charge Voltage15.6VDischarge Cut-off Voltage8V
Nominal Capacity100AhRated Energy1200Wh
Electrical Performance
Maximum Charge Current100AMaximum Continuous Discharge Current100A
Maximum Peak Discharge Current (5S)200AMaximum Series & Parallel4S4P
Temperature & Protection
Charge Temperature-10~+60°CDischarge Temperature-30~+60°C
IP Rating of EnclosureIP65Protection LevelIP65
Physical & Installation
TerminalsM8Dimension332*172*220mm
Weight13.5kg
Lifecycle & Compliance
Cycle Life≥4000LCD ScreenRegular LCD screen

FAQ

What is the LN12100N-BL and where is it used?

The LN12100N-BL is intended for lead-acid replacement and backup-power applications requiring a sodium-ion solution. Its listed core specifications are 12V nominal voltage, 100Ah nominal capacity, 1200Wh rated energy. Final compatibility must be confirmed against the equipment voltage, load and mechanical space.

How should the LN12100N-BL be charged?

Use a charger whose chemistry, voltage and current settings match the LN12100N-BL. The listed charging limits are maximum charge voltage 15.6V, maximum charge current 100A. Charger profile, connector polarity and BMS settings should be verified before use.

What discharge performance does the LN12100N-BL provide?

Discharge capability must be matched to the equipment's continuous and startup loads. The listed values are discharge cut-off voltage 8V, maximum continuous discharge current 100A, 5-second peak current 200A, cycle life ≥4000. Cable gauge, fusing and protection settings must be sized for the complete system.

What are the size, weight and temperature limits of the LN12100N-BL?

For the LN12100N-BL, the listed physical and environmental specifications are dimensions 332*172*220mm, weight 13.5kg, charge temperature -10~+60°C, discharge temperature -30~+60°C. Connector, wire and enclosure options can change final dimensions and weight.

Can the LN12100N-BL be customized for an OEM project?

Hysincere can review the LN12100N-BL for OEM/ODM integration, including connector, wire, enclosure, BMS and labeling requirements. Product-specific notes: listed series/parallel support: 4S4P; protection level: IP65. Provide the device voltage, normal and peak current, installation space, operating temperature and required certifications for engineering confirmation.